Core and Whole-Body Vibration Exercise Improve Military Foot March Performance in Novice Trainees: A Randomized Controlled Trial.

Abstract

INTRODUCTION: The purpose of the present study was to investigate core exercise training and whole-body vibration (WBV) as a training method to improve performance and recovery from an 8-km military foot march in novice trainees. MATERIALS AND METHODS: A 3 x 5 repeated measures randomized control trial was used to evaluate the effects of core exercise training and WBV on performance and recovery from an 8-km foot march. Thirty-nine participants were randomized into three groups: core exercise (Ex), WBV with core exercise (WBVEx), and control. Each participant completed two 8-km foot marches (FM1 and FM2) with a 35 pound rucksack, separated by 4 weeks. Participants in the Ex and WBVEx groups completed 3 weeks of core exercise training, three times per week in between FM1 and FM2. Performance time, creatine kinase (CK), and interleukin-6 (IL-6) were measured. The Auburn University Institutional Review Board approved all aspects of this study (protocol number: 19-211 MR 1907). RESULTS: Performance time (P < .001) and CK (P = .005) were significantly improved during FM2 as compared to FM1. The Ex (d = -0.295) and WBVEx (d = -0.645) treatments had a large effect on performance time. CK (P < .001) and IL-6 (P < .001) were significantly elevated at the completion of the foot march regardless of group. Only CK remained elevated for 2 days (P < .001) following the foot march. CONCLUSIONS: Core exercise training with or without WBV improved 8-km foot march performance time by 5-6 minutes. The improvements are likely because of an increase in trunk stability. Additionally, this study showed that completing two identical foot marches a month apart increases performance and improves recovery.

Autor: Lyons KD, Parks AG, Dadematthews OD, Zandieh NL, McHenry PA, Games KE, Goodlett MD, Murrah WM, Roper JA, Sefton JM

Organisation: Warrior Research Center, School of Kinesiology, Auburn University, Auburn, AL 36849, USA.

Jahr: 2021

GID: 5492

Erstellt am: 19.07.2021

Das Urteil unserer Kunden: Hervorragend

4.7/5

4,7 von 5 Sternen basierend auf 868 Bewertungen

TÜV zertifiziert

Wir sind vom TÜV zertifizierter Hersteller für Medizinprodukte.

Made in Germany

Die Entwicklung und Herstellung findet nur in Deutschland statt.

Bewährte Qualität

10 Jahre Servicegarantie & mehr als 35 Jahre Erfahrung im Firmenverbund.

Studien

Über 2000 wissenschaftliche Publikationen zu unseren Produkten.

Weltweit Tätig

Mit unseren Vertriebspartnern international tätig.

Fangen Sie an zu tippen, um die gesuchten Beiträge zu sehen.