Galileo Research Facts No. 173: Can Galileo Training increase Oxygen uptake compared to traditional exercises?

Galileo Research Facts No. 173: Can Galileo Training increase Oxygen uptake compared to traditional exercises?

This study investigated the effects of squats and heel raises with extra loads on muscle function and cross-section with and without Galileo Training at 40Hz (20-40Hz, pos. 3-4, loads 80% 1RM (80kg), 3×8 squats (4 sec.), 3×12 heel raises, 6 weeks, 16 Sessions). The Galileo group showed with 5-12% lower additional training mass a significantly higher oxygen uptake (+15%) and therefore a higher training efficiency…

Galileo Research Facts No. 167: Are Joint Torques during Galileo Training Dependent on Frequency and Amplitude?

Galileo Research Facts No. 167: Are Joint Torques during Galileo Training Dependent on Frequency and Amplitude?

This study investigates the effects of Frequency and Amplitude during Galileo Training on joint torques (10, 20, 30Hz, pos.1, pos.2, pos.3, upright standing with straight legs). Joint torque showed an significant increase with increasing frequency and amplitude of up to 250% – nevertheless joint torques stayed below those of natural walking…

Galileo Research Facts No. 164: Can static exercises with Galileo Training be more effective than dynamic exercises?

Galileo Research Facts No. 164: Can static exercises with Galileo Training be more effective than dynamic exercises?

This study documented the effects of Galileo Training in combination with squats on the heart rate. Dynamic as well as static squats with and without Galileo were tested (26Hz, Pos. 3). The Galileo groups showed significantly higher effects on the heart rate compared to the control group with +42% and +47%. The static squats was 13% more effective than the dynamic exercises…

Galileo Research Facts No. 162: Can Galileo Training improve movement efficiency?

Galileo Research Facts No. 162: Can Galileo Training improve movement efficiency?

This study investigated short-term effects of Galileo Training on movement efficiency (30Hz, Pos. 2, 1 min., 10% knee angle, fore-foot stance, 2×8 repetitions). The maximum ankle torque and muscle activation (EMG) was tested. After the Galileo application the torque was constant but muscle activation as well as co-contraction was decreased and hence movement efficiency was increased significantly…

Galileo Research Facts No. 160: Does Galileo Training induce larger forces than in walking?

Galileo Research Facts No. 160: Does Galileo Training induce larger forces than in walking?

This study measured the ground reaction forces during Galileo Training (forces induced into the body) (10 – 30Hz, Pos.1 – Pos.3, upright standing, locked knees). Ground reaction forces showed values below body weight (<1g) while typical peak forces during walking are in the range of 1.2 times body weight – this shows once more the high safety aspects of Galileo Training…

Galileo Research Facts No. 158: Is Galileo Training more effective to activate Postural Control than Balance Training?

Galileo Research Facts No. 158: Is Galileo Training more effective to activate Postural Control than Balance Training?

This Study observed short-term effects of Galileo Training on Postural Control compared to traditional balance training (25Hz, pos. 2, 2 min., almost straight leg, on forefoot). The Galileo group showed better results than the Wobble-Board group. The combination of reduction of co-contraction (-18%) and of H-Reflexes (-31%) resulted in an significant improvement of Postural Control (covered balance area -8%)…

Galileo Research Facts No. 151: Can Galileo Training make squats more efficient and more effective?

Galileo Research Facts No. 151: Can Galileo Training make squats more efficient and more effective?

This study reported the short-term effects of Galileo Training on muscle activation and exhaustion (26Hz, 90° dynamic squats, Pos. 6, 40% body weight extra load, subjective exhaustion). The control group received identical exercises without Galileo. The Galileo groups showed higher training effects (increase lactate +205% instead of +160%) in significantly shorter time (349s instead of 515s) plus increased muscle activation…

Galileo Research Facts No. 149: Can Galileo Training significantly increase force and force development?

Galileo Research Facts No. 149: Can Galileo Training significantly increase force and force development?

This study investigated the short-term effect of Galileo Training on force and force development (26Hz, 40° squat, Pos. 3, 5Min). The control group received identical exercises without Galileo or cycling ergometer (70W). Force and force development during electrostimulation was measured. While both control groups reduced the parameters 5 minutes of Galileo Training could increase force and force development significantly…

Galileo Research Facts No. 147: Can Galileo Training compensate the effects of bedrest on the Bone Marrow Fat-Fraction?

Galileo Research Facts No. 147: Can Galileo Training compensate the effects of bedrest on the Bone Marrow Fat-Fraction?

In the 2nd Berlin Bedrest Study (BBR2) the effects of Galileo Training against the expected bone loss was tested (55 days, 24Hz, 6×1 min. exhaustive, 3/week). The control groups receive no training or identical training with-out vibration (RE). Compared to both control groups, the Galileo group showed a decrease in vertebra bone marrow fat fraction and in increase in number of red blood cells – both are related to increased endurance…

Galileo Research Facts No. 146: Can exercises with extra loads and with Galileo Training at 40Hz be more effective than without?

Galileo Research Facts No. 146: Can exercises with extra loads and with Galileo Training at 40Hz be more effective than without?

This study investigated the effects of squats and heel raises with extra loads on muscle function and cross-section with and without Galileo Training at 40Hz (20-40Hz, pos. 3-4, loads 80% 1RM (80kg), 3×8 squats (4 sec.), 3×12 heel raises, 6 weeks, 16 Sessions). The Galileo Group showed higher training effects with increases of isometric torque (up to +4%) and the speed indicator reactive ground contact time (-8%, Drop Jump)…