Estimation of Peak Muscle Power From a Countermovement Vertical Jump in Children and Adolescents.

Abstract

Several equations to predict muscle power (MP) from vertical jump height (VJH) have been developed in adults. However, few have been derived in children. We therefore aimed to: (a) evaluate the validity of existing MP estimation equations from a vertical countermovement jump (CMJ) in children and adolescents and (b) develop and validate a new MP estimation equation for use in children and adolescents. We measured peak MP (in watts) and VJH (in centimeters) during a CMJ using a force platform in 249 children and adolescents (9-17 years; 119 boys and 130 girls). We compared actual (force platform) with predicted (12 existing prediction equations) MP using repeated-measures analysis of variance and estimated bias using modified Bland-Altman plots. We developed a new prediction equation using stepwise linear regression, assessed predictive error using leave-one-out and 10-fold cross-validation, and externally validated the equation in an independent sample (n = 100). All existing prediction equations demonstrated some degree of bias, either systematic bias (mean differences ranging 178-1,377 W; 8-64%) or bias at the extremes or interactions with sex. Our new prediction equation estimates MP from VJH and body mass: Power (W) = 54.2 x VJH (cm) + 34.4 x body mass (kg) – 1,520.4. With this new equation, there was no difference between actual and predicted MP (0%) and negligible differences (0.2-0.9%) in R and root mean square error between our observed and cross-validated sets. Actual and predicted MP were not different in our external validation (p = 0.12). The new equation demonstrates excellent validity and can be used to predict MP from a CMJ in children and adolescents.

Author: Gomez-Bruton A, Gabel L, Nettlefold L, Macdonald H, Race D, McKay H

Organization: GENUD Research Group, Faculty of Health and Sport Sciences, University of Zaragoza, Zaragoza, Spain.

Year: 2019

GID: 5989

Created on: 11.05.2023

The verdict of our customers: Excellent

4.7/5

4.7 out of 5 stars based on 868 reviews

TÜV certified

We are a TÜV certified manufacturer for medical products.

Made in Germany

Development and manufacturing in Germany.

Proven quality

10 years service guarantee & more than 35 years experience in the company group.

Research studies

over 2000 scientific publications about our products.

Active worldwide

Internationally active with our distribution partners.

Start typing to see posts you are looking for.