Effects of whole-body vibrations on neuromuscular fatigue: a study with sets of different durations.

Abstract

Background: Whole body vibrations have been used as an exercise modality or as a tool to study neuromuscular integration. There is increasing evidence that longer WBV exposures (up to 10 minutes) induce an acute impairment in neuromuscular function. However, the magnitude and origin of WBV induced fatigue is poorly understood. Purpose: The study aimed to investigate the magnitude and origin of neuromuscular fatigue induced by half-squat long-exposure whole-body vibration intervention (WBV) with sets of different duration and compare it to non-vibration (SHAM) conditions. Methods: Ten young, recreationally trained adults participated in six fatiguing trials, each consisting of maintaining a squatting position for several sets of the duration of 30, 60 or 180 seconds. The static squatting was superimposed with vibrations (WBV30, WBV60, WBV180) or without vibrations (SHAM30, SHAM60, SHAM180) for a total exercise exposure of 9-minutes in each trial. Maximum voluntary contraction (MVC), level of voluntary activation (%VA), low- (T20) and high-frequency (T100) doublets, low-to-high-frequency fatigue ratio (T20/100) and single twitch peak torque (TWPT) were assessed before, immediately after, then 15 and 30 minutes after each fatiguing protocol. Result: Inferential statistics using RM ANOVA and post hoc tests revealed statistically significant declines from baseline values in MVC, T20, T100, T20/100 and TWPT in all trials, but not in %VA. No significant differences were found between WBV and SHAM conditions. Conclusion: Our findings suggest that the origin of fatigue induced by WBV is not significantly different compared to control conditions without vibrations. The lack of significant differences in %VA and the significant decline in other assessed parameters suggest that fatiguing protocols used in this study induced peripheral fatigue of a similar magnitude in all trials.

Further information:

Author: Kalc M, Ritzmann R, Strojnik V

Organization: Faculty of Medicine, Institute of Sports Medicine, University of Maribor, Maribor, Slovenia.

Year: 2020

GID: 5246

Created on: 08.12.2020

The verdict of our customers: Excellent

4.7/5

4.7 out of 5 stars based on 868 reviews

TÜV certified

We are a TÜV certified manufacturer for medical products.

Made in Germany

Development and manufacturing in Germany.

Proven quality

10 years service guarantee & more than 35 years experience in the company group.

Research studies

over 2000 scientific publications about our products.

Active worldwide

Internationally active with our distribution partners.

Start typing to see posts you are looking for.