Peripheral quantitative computed tomography (pQCT) measures are associated with prior low trauma fracture in men.

Abstract

Peripheral quantitative computed tomography (pQCT) assesses bone quantity and quality, complementary to current standard practice, and has potential to improve prediction of fracture risk. This study explored whether pQCT parameters were associated with prior fracture in men and found a number of parameters to be associated, particularly at the radius. PURPOSE: Peripheral quantitative computed tomography (pQCT) provides information about bone structure and density complementary to dual x-ray absorptiometry. This study aimed to determine which pQCT parameters are associated with prior fracture. METHODS: Participants were men (n = 508, age 33-96 years) from the Geelong Osteoporosis Study. Parameters at 4% (n = 469) and 66% (n = 436) of radial length, and 4% (n = 449) and 66% (n = 437) of tibial length were acquired (pQCT XCT 2000, Stratec Medizintechnik, Pforzheim, Germany), and mean standardised. Low trauma prior fractures in adulthood (>/= age 20 years) were radiologically confirmed when possible. Cross-sectional associations between pQCT and fracture were tested using logistic regression adjusting for confounders. RESULTS: Prior low trauma fractures were identified for 106 participants. Fracture was negatively associated with parameters at the 4% radius site: bone mass (adjusted OR = 0.67; 95%CI = 0.52-0.86), total density (OR = 0.61; 95%CI = 0.47-0.78), trabecular density (OR = 0.62; 95%CI = 0.48-0.79) and cortical subdensity (OR = 0.61; 95%CI = 0.47-0.77). At the 66% radius site, fracture was associated with total density (OR = 0.69; 95%CI = 0.55-0.87) and cortical thickness (OR = 0.68; 95%CI = 0.54-0.86). Fracture was associated with the ratio of the cortical area at the 66% site to the total area at the 4% site (OR = 0.74; 95%CI = 0.58-0.94). Prior fracture was negatively associated with parameters at the 4% tibial site: total density (OR = 0.67; 95%CI = 0.52-0.86), trabecular density (OR = 0.64; 95%CI = 0.50-0.82) and cortical subdensity (OR = 0.72; 95%CI = 0.56-0.92). Fracture was negatively associated with cortical density at the 66% site (OR = 0.74; 95%CI = 0.58-0.94), and the ratio of the cortical area at the 66% site to the total area at the 4% site (OR = 0.65; 95%CI = 0.46-0.91), but were attenuated in adjusted models. No other associations were identified. CONCLUSION: Prior fracture was associated with parameters at both the radius and tibia. This study highlights key pQCT parameters that may aid in the prediction of fracture risk.

Autor: Anderson KB, Tembo MC, Sui SX, Hyde NK, Pasco JA, Kotowicz MA, Holloway-Kew KL

Organisation: Epi-Centre for Healthy Ageing (ECHA), IMPACT (Institute for Mental and Physical Health and Clinical Translation), Deakin University, PO Box 281, Barwon Health, Geelong, VIC, 3220, Australia. k.anderson@deakin.edu.au.

Jahr: 2021

GID: 5595

Erstellt am: 30.11.2021

Das Urteil unserer Kunden: Hervorragend

4.7/5

4,7 von 5 Sternen basierend auf 868 Bewertungen

TÜV zertifiziert

Wir sind vom TÜV zertifizierter Hersteller für Medizinprodukte.

Made in Germany

Die Entwicklung und Herstellung findet nur in Deutschland statt.

Bewährte Qualität

10 Jahre Servicegarantie & mehr als 35 Jahre Erfahrung im Firmenverbund.

Studien

Über 2000 wissenschaftliche Publikationen zu unseren Produkten.

Weltweit Tätig

Mit unseren Vertriebspartnern international tätig.

Fangen Sie an zu tippen, um die gesuchten Beiträge zu sehen.