Abstract

Objective:
The interest in vibration as a method of enhancing muscular performance is receiving considerable attention from sport scientists, physiotherapists, coaches and athletes. Increases in strength, power and jump height have been reported after a single session of whole body vibration. In some cases, this immediate change has been attributed to changes in the stiffness of the musculotendinous complex without directly measuring the stiffness properties of muscle. The aim of this study was to determine whether whole body vibration had an effect on the stiffness of the triceps surae muscle group.
Design:
The stiffness of the right and left leg of 11 relatively untrained subjects was measured prior to a warm-up, post-warm-up and post-vibration using a damped oscillation technique. After warm-up, one leg was vibrated (frequency 26 Hz, amplitude 6 mm) whilst the other leg acted as a control. The subjects were exposed to the vibration five times for a duration of 60 s with a 60 s rest between each repetition.
Results:
No significant differences (P>0.05) in stiffness were found between the baseline measures and the post-warm-up and post-vibration measures of stiffness. Following vibration a number of subjects experienced pain to the lower leg muscles and a loss of function. In some subjects, the pain was experienced at the jaw and the neck. These symptoms required treatment in six subjects but the pain had resolved within 7–10 days in all subjects.
Conclusions:
It appears that vibratory stimulation loading parameters used to enhance performance do not significantly alter muscle stiffness in untrained individuals. Considering the injury potential associated with whole body vibration further research into safe dose-response relationships is recommended.

Autor: Cronin, JB, Olivera M, McNairb PJ

Organisation: Sport Performance Research Centre, Auckland University of Technology, Private Bag 92006, Auckland 1020, New Zealand; Neuromuscular Research Unit, School of Physiotherapy, Auckland University of Technology, Private Bag 92006, Auckland 1020, New Zealand

Jahr: 2004

GID: 449

Erstellt am: 06.12.2007

Das Urteil unserer Kunden: Hervorragend

4.7/5

4,7 von 5 Sternen basierend auf 868 Bewertungen

TÜV zertifiziert

Wir sind vom TÜV zertifizierter Hersteller für Medizinprodukte.

Made in Germany

Die Entwicklung und Herstellung findet nur in Deutschland statt.

Bewährte Qualität

10 Jahre Servicegarantie & mehr als 35 Jahre Erfahrung im Firmenverbund.

Studien

Über 2000 wissenschaftliche Publikationen zu unseren Produkten.

Weltweit Tätig

Mit unseren Vertriebspartnern international tätig.

Fangen Sie an zu tippen, um die gesuchten Beiträge zu sehen.