Balance and prospective falls in patients with rheumatoid arthritis.

Abstract

BACKGROUND: Postural control is associated with fall risk. Patients with rheumatoid arthritis (RA) have a higher risk to fall than healthy subjects. The objective of this study was to identify associations between variables of postural control with prospective falls in patients with RA. METHODS: For the baseline, the balance performance of 289 men and women with RA, ages 24-85 years, was evaluated by SPPB, FICSIT-4 and Romberg tests. Postural sway for Romberg, semitandem, tandem and one-leg stands were measured with the Leonardo Mechanograph(R). Self-reported disability was assessed using the Health Assessment Questionnaire (HAQ) and the Activity-specific Balance Confidence Scale (ABC-scale). Falls were reported in quarterly reports over a year. Univariate and multiple logistic regression analysis were used to explore any associations with falling. Receiver-operating characteristics were determined, and the area under the curve is reported. RESULTS: A total of 238 subjects completed the 1-year follow-up, 48 (20.2%) experienced at least one fall during the observational period. Age (OR = 1.04, CI 1.01-1.07), HAQ (OR = 1.62, 1.1-2.38), FICSIT-4 scoring 0-4 (OR = 2.38, 1.13-5.0), and one-leg standing (OR = 2.14, 1.06-4.31) showed significant associations with falls. With regard to the SPPB and ABC-scale, no statistically significant associations with falls were found. The quartiles containing the worst results of medio-lateral sway of Romberg (OR = 2.63, CI 1.03-6.69), total sway of semitandem (OR = 3.07, CI 1.10-8.57) and tandem (OR = 2.86, CI 1.06-7.69), and area of sway of semitandem (OR = 2.80, CI 1.11-7.08) stands were associated with falls. CONCLUSIONS: The assessment of a one-leg stand seems to be a good screening tool to discriminate between high and low risk of falls in RA patients in clinical practice. A low FICSIT-4 score and several sway parameters are important predictors of falls. TRIAL REGISTRATION: The study has been registered at the German Clinical Trials Register and the WHO International Clinical Trials Registry Platform (ICTRP) since 16 March 2017 ( DRKS00011873 ).

Autor: Wiegmann S, Armbrecht G, Borucki D, Buehring B, Buttgereit F, Detzer C, Schaumburg D, Zeiner KN, Dietzel R

Organisation: Department of Radiology, Centre for Muscle and Bone Research, Charite - Universitatsmedizin Berlin, corporate member of Freie Universitat Berlin and Humboldt- Universitat zu Berlin, Hindenburgdamm 30, 12200, Berlin, Germany. sabine.wiegmann@charite.de.

Jahr: 2022

GID: 6135

Erstellt am: 08.02.2024

Das Urteil unserer Kunden: Hervorragend

4.7/5

4,7 von 5 Sternen basierend auf 868 Bewertungen

TÜV zertifiziert

Wir sind vom TÜV zertifizierter Hersteller für Medizinprodukte.

Made in Germany

Die Entwicklung und Herstellung findet nur in Deutschland statt.

Bewährte Qualität

10 Jahre Servicegarantie & mehr als 35 Jahre Erfahrung im Firmenverbund.

Studien

Über 2000 wissenschaftliche Publikationen zu unseren Produkten.

Weltweit Tätig

Mit unseren Vertriebspartnern international tätig.

Fangen Sie an zu tippen, um die gesuchten Beiträge zu sehen.