Ankle flexor/extensor strength and muscle density are complementary determinants of balance during dual-task engagement: The ankle quality study

Abstract

Background
This study investigated relative contributions of ankle flexor torque, muscle size, and density on balance and falls.

Methods
Men and women =50 years of age completed a peripheral quantitative computed tomography scan of the mid-leg to quantify muscle density (MD) and cross-sectional area; Biodex dynamometry to evaluate maximal isometric ankle flexor torque; and a single-leg balance test on a force platform with/without eyes closed and cognitive task. Ankle flexor torque, muscle size, and density individually, together, or as interactions were examined for associations with balance (mean step duration, steps/trial) in general linear models, or with falls in Poisson regression, adjusting for age, sex, BMI, glucocorticoid use, osteoarthritis, and physical activity. Visuo-cognitive conditions were compared.

Results
Among 105 participants (age: 63.3 ± 9.9 years, BMI: 25.8 ± 5.4 kg/m2, 77.1% female), 41.8% experienced =1 fall in the last year. Balance on one leg was dependent on ankle flexor torque when eyes were open (r = -0.220 to -0.284) and on having leaner mid-leg muscles when eyes were closed (r = -0.123 to -0.142); cognitive challenge blunted these correlations. Individuals with leaner muscles tended to rely more on plantarflexors than dorsiflexors. A 2% lower step-free fraction in the eyes-closed paradigm associated with having 1 additional fall [-0.701(-1.235, -0.167)], but neither torque, muscle density, nor size related to number of falls.

Conclusions
Among ambulatory adults, ankle flexor torque and muscle density showed an interactive influence on balance that depended on visuo-cognitive input. The complementary roles of torque and muscle density on balance suggest redundancy is important under dual-tasking conditions.

Weitere Informationen:

Autor: Andy K. O. Wong, Hugo J. W. Fung, Steven P. Pretty, Andrew C. Laing, Adrian H. Chan, Sunita Mathur, Karl Zabjek, Lora Giangregorio, Angela M. Cheung

Organisation: Andy K. O. Wong, Hugo J. W. Fung, Steven P. Pretty, Andrew C. Laing, Adrian H. Chan, Sunita Mathur, Karl Zabjek, Lora Giangregorio, Angela M. Cheung

Jahr: 2023

GID: 5915

Erstellt am: 25.02.2023

Das Urteil unserer Kunden: Hervorragend

4.7/5

4,7 von 5 Sternen basierend auf 868 Bewertungen

TÜV zertifiziert

Wir sind vom TÜV zertifizierter Hersteller für Medizinprodukte.

Made in Germany

Die Entwicklung und Herstellung findet nur in Deutschland statt.

Bewährte Qualität

10 Jahre Servicegarantie & mehr als 35 Jahre Erfahrung im Firmenverbund.

Studien

Über 2000 wissenschaftliche Publikationen zu unseren Produkten.

Weltweit Tätig

Mit unseren Vertriebspartnern international tätig.

Fangen Sie an zu tippen, um die gesuchten Beiträge zu sehen.