Mechanography assessment of fall risk in older adults: the Vietnam Osteoporosis Study.

Abstract

BACKGROUND: Jumping mechanography is a technology for quantitatively assessing muscular function and balance in older adults. This study sought to define the association between jumping mechanography parameters and fall risk in Vietnamese individuals. METHODS: The study involved 375 women and 244 men aged 50 years and older, who were recruited from the general population in Ho Chi Minh City (Vietnam). The individuals had been followed for 2 years. At baseline, Esslinger Fitness index (EFI), jumping power, force, velocity of lower limbs, and the ability to maintain balance were measured by a Leonardo Mechanograph Ground Reaction Force system (Novotec Medical, Pforxheim, Germany). The incidence of falls during the follow-up period was ascertained from self-report. Logistic regression analysis was used to analyse the association between jumping mechanography parameters and fall risk. RESULTS: The average age of participants at baseline was 56.7 years (SD 5.85). During the 2 year follow-up, 92 falls were reported, making the incidence of fall at ~15% [95% confidence interval (CI), 12.1 to 18.2]. The incidence of fall increased with advancing age, and women had a higher incidence than men (17.6% vs. 10.7%; P = 0.024). In univariate analysis, maximal velocity [odds ratio (OR) 0.65; 95% CI, 0.52 to 0.82], maximal force (OR 0.83; 95% CI, 0.65 to 1.04), and maximal power (OR 0.68; 95% CI, 0.52 to 0.88) were each significantly associated with fall risk. EFI was not significantly associated with fall risk (OR 1.09; 95% CI, 0.86 to 1.39). However, in a multiple logistic regression model, greater maximum velocity was associated with lower odds of fall (OR 0.38; 95% CI, 0.16 to 0.92). CONCLUSIONS: These data suggest that jumping mechanography is a useful tool for assessing fall risk in older adults of Vietnamese background.

Further information:

Author: Hoang DK, Le NM, Vo-Thi UP, Nguyen HG, Ho-Pham LT, Nguyen TV

Organization: Bone and Muscle Research Group, Ton Duc Thang University, Ho Chi Minh City, Vietnam.

Year: 2021

GID: 5464

Created on: 02.07.2021

The verdict of our customers: Excellent

4.7/5

4.7 out of 5 stars based on 868 reviews

TÜV certified

We are a TÜV certified manufacturer for medical products.

Made in Germany

Development and manufacturing in Germany.

Proven quality

10 years service guarantee & more than 35 years experience in the company group.

Research studies

over 2000 scientific publications about our products.

Active worldwide

Internationally active with our distribution partners.

Start typing to see posts you are looking for.