Associations between parameters of peripheral quantitative computed tomography and bone material strength index.

Abstract

Background: Bone material strength index (BMSi) is measured in vivo using impact microindentation (IMI). However, the associations between BMSi and other bone measures are not clear. This study investigated whether bone parameters derived by peripheral quantitative computed tomography (pQCT) are associated with BMSi.

Methods: Participants were men (n = 373, ages 34-96 yr) from the Geelong Osteoporosis Study. BMSi was measured using an OsteoProbe (Active Life Scientific, USA). Bone measures were obtained at both the radius (n = 348) and tibia (n = 342) using pQCT (XCT 2000 Stratec Medizintechnik, Germany). Images were obtained at 4% and 66% of radial and tibial length. Associations between pQCT parameters and BMSi were tested using Spearman’s correlation and multivariable regression used to determine independent associations after adjustment for potential confounders. Models were checked for interaction terms.

Results: Weak associations were observed between total bone density (radius 4%; r = +0.108, p = 0.046, tibia 4%; r = +0.115, p = 0.035), cortical density (tibia 4%; r = +0.123, p = 0.023) and BMSi. The associations were independent of weight, height, and glucocorticoid use (total bone density: radius 4%; ß = 0.020, p = 0.006, tibia 4%; ß = 0.020, p = 0.027 and cortical density: radius 4%; ß = 4.160, p = 0.006, tibia 4%; ß = 0.038, p = 0.010). Associations with bone mass were also observed at the 66% radial and tibial site, independent of age, weight, and glucocorticoid use (ß = 4.160, p = 0.053, ß = 1.458, p = 0.027 respectively). Total area at the 66% tibial site was also associated with BMSi (ß = 0.010, p = 0.012), independent of weight and glucocorticoid use. No interaction terms were identified.

Conclusion: There were weak associations detected between some pQCT-derived bone parameters and BMSi.

Author: Holloway-Kew KL, Rufus-Membere P, Anderson KB, Tembo MC, Sui SX, Hyde NK, Diez-Perez A, Kotowicz MA, Pasco JA

Organization: Deakin University, IMPACT - the Institute for Mental and Physical Health and Clinical Translation, School of Medicine, Geelong, Australia. Electronic address: k.holloway@deakin.edu.au.

Year: 2022

GID: 5600

Created on: 06.12.2021

The verdict of our customers: Excellent

4.7/5

4.7 out of 5 stars based on 868 reviews

TÜV certified

We are a TÜV certified manufacturer for medical products.

Made in Germany

Development and manufacturing in Germany.

Proven quality

10 years service guarantee & more than 35 years experience in the company group.

Research studies

over 2000 scientific publications about our products.

Active worldwide

Internationally active with our distribution partners.

Start typing to see posts you are looking for.