Differential shock transmission response of the human body to impact severity and lower limb posture

Abstract

The shocks imparted to the foot during locomotion may lead to joint-degenerative diseases and jeopardize the visual-vestibular functions. The body relies upon several mechanisms and structures that have unique viscoelastic properties for shock attenuation. The purpose of the present study was to determine whether impact severity and initial knee angle (IKA) could alter the shock transmission characteristics of the body. Impacts were administered to the right foot of 38 subjects with a human pendulum device. Combinations of velocities (0.9, 1.05 and 1.2 m s-1) and surfaces (soft and hard foams) served to manipulate impact severity in the first experiment. Three IKA (0, 20 and 40 degrees) were examined in the second experiment. Transmission between shank and head was characterized by measuring the shock at these sites with miniature accelerometers. Velocity and surface had no effect on the frequency profile of shock transmission suggesting a consistent response of the body to impact severity. Shank shock power spectrum features accounted for the lower shock ratio (head/shank) measured under the hard surface condition. IKA flexion caused considerable reduction in effective axial stiffness of the body (EASB), 28.7-7.9 kNm-1, which improved shock attenuation. The high correlation (r = 0.97) between EASB and shock ratio underscored the importance of EASB to shock attenuation. The present findings provide valuable information for the development of strategies aimed at protecting the joints, articular cartilage, spine and head against locomotor shock.

Autor: Lafortune MA, Lake MJ, Hennig EM

Organisation: School of Human Biology, University of Guelph, Ontario, Canada.

Jahr: 1996

GID: 29

Erstellt am: 16.12.2007

Das Urteil unserer Kunden: Hervorragend

4.7/5

4,7 von 5 Sternen basierend auf 868 Bewertungen

TÜV zertifiziert

Wir sind vom TÜV zertifizierter Hersteller für Medizinprodukte.

Made in Germany

Die Entwicklung und Herstellung findet nur in Deutschland statt.

Bewährte Qualität

10 Jahre Servicegarantie & mehr als 35 Jahre Erfahrung im Firmenverbund.

Studien

Über 2000 wissenschaftliche Publikationen zu unseren Produkten.

Weltweit Tätig

Mit unseren Vertriebspartnern international tätig.

Fangen Sie an zu tippen, um die gesuchten Beiträge zu sehen.

Winterferien

Liebe Kunden,

unsere Kolleginnen und Kollegen waren das ganze Jahr für Sie und Ihre Wünsche im Einsatz – jetzt gönnen wir ihnen eine wohlverdiente Pause. Vom 24.12.2024 bis 6.1.2025 tauschen wir Telefone gegen Weihnachtsfilme und To-do-Listen gegen Plätzchenteller.

Unser Kontaktformular bleibt jedoch wachsam wie ein Weihnachtsengel – schreiben Sie uns gern, und wir melden uns ab dem 7.1.2025, wenn wir erholt und voller Tatendrang zurück sind!

Frohe Weihnachten und einen zauberhaften Jahreswechsel wünscht
Ihr Galileo-Team