{"id":162492,"date":"2025-01-20T14:10:12","date_gmt":"2025-01-20T13:10:12","guid":{"rendered":"https:\/\/stratec-med.com\/literatur\/reproducibility-of-the-jumping-mechanography-as-a-test-of-mechanical-power-output-in-physically-competent-adult-and-elderly-subjects-2\/"},"modified":"2025-01-20T14:10:13","modified_gmt":"2025-01-20T13:10:13","slug":"reproducibility-of-the-jumping-mechanography-as-a-test-of-mechanical-power-output-in-physically-competent-adult-and-elderly-subjects-2","status":"publish","type":"literatur","link":"https:\/\/stratec-med.com\/en\/literature\/reproducibility-of-the-jumping-mechanography-as-a-test-of-mechanical-power-output-in-physically-competent-adult-and-elderly-subjects-2\/","title":{"rendered":"Reproducibility of the jumping mechanography as a test of mechanical power output in physically competent adult and elderly subjects"},"content":{"rendered":"<p>OBJECTIVES: To compare the reproducibility of the newly developed jumping mechanography with other physical tests. DESIGN: Study 1: Repeated testing with an interval of 2 weeks to assess the short-term repetition error. Study 2: Testing on 5 successive days to assess learning effects. SETTING: Geriatric clinic, Esslingen, Germany. PARTICIPANTS: Study 1 had 36 subjects aged 24 to 88; Study 2 had 22 subjects aged 19 to 86. Locomotor competence in all subjects was assessed using the ability to walk unaided and to perform a tandem stand and tandem walk. MEASUREMENTS: The test battery consisted of timed up and go, freely chosen gait speed, maximum gait speed, chair-rising test, and maximum power in jumping mechanography. RESULTS: All subjects performed the jumping mechanography without major problems. Study 1: Of all tests, maximum power in jumping mechanography depicted the smallest intrasubject short-term error (3.6%), the largest intersubject coefficient of variation (45.4%), and the greatest test-retest correlation coefficient (r=0.99). Study 2: The only tests for which the learning effects were confined to the 1% range were the maximum gait speed test and the maximum power in jumping mechanography. CONCLUSION: Assessment of maximum power in jumping mechanography appears to have good test-retest reliability with negligible learning effects. Moreover, it results in a comparatively large intersubject variability, which makes it an interesting method in the assessment of aging effects in middle-aged to older subjects and patients.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>OBJECTIVES: To compare the reproducibility of the newly developed jumping mechanography with other physical tests. DESIGN: Study 1: Repeated testing<\/p>\n","protected":false},"author":22,"parent":0,"menu_order":0,"template":"","format":"standard","meta":{"_acf_changed":false},"tags":[1243],"thema":[5870,5922,5924,5866,5878,5880,5856,5858],"produktgruppe":[5827],"literatur_kategorie":[7221],"class_list":["post-162492","literatur","type-literatur","status-publish","format-standard","hentry","tag-mechanography","thema-basics","thema-clinical-application","thema-clinical-studies","thema-diagnostics-using-leonardo-pqct","thema-medical-applications","thema-pyhsitherapy-rehabilitation","thema-therapy-prevention-using-galileo","thema-training-with-galileo","produktgruppe-leonardo-en","literatur_kategorie-clinical-studies"],"acf":[],"_links":{"self":[{"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/literatur\/162492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/literatur"}],"about":[{"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/types\/literatur"}],"author":[{"embeddable":true,"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/users\/22"}],"version-history":[{"count":0,"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/literatur\/162492\/revisions"}],"wp:attachment":[{"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/media?parent=162492"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/tags?post=162492"},{"taxonomy":"thema","embeddable":true,"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/thema?post=162492"},{"taxonomy":"produktgruppe","embeddable":true,"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/produktgruppe?post=162492"},{"taxonomy":"literatur_kategorie","embeddable":true,"href":"https:\/\/stratec-med.com\/en\/wp-json\/wp\/v2\/literatur_kategorie?post=162492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}